Product Overview
This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety switch, PNP, NPN sensor, RFID safety switch, Safety light curtain or Sensing mat/edges. The safety relay is powered with 48-240V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 positive 1 negative safety inputs, 4 ON/OFF configurable pulsed outputs, 3 NO immediate, 3 NO configurable, 1 NC configurable safety outputs, 2 solid state diagnostic outputs. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,350kg. Its dimensions are 45mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,350kg. Its dimensions are 45mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÜV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandSchneider Electric
Amperage Rating5 A, 5:00 AM
Contact FormMechanical
Country of OriginID
Dimensions3.94 in H x 1.77 in W x 4.72 in D
Enclosure TypeIP20/IP40/IP54
Frequency Rating50/60 Hz
Manufacturer NameSchneider Electric
Power Rating4 W
SeriesXPS
Temperature Rating-13 to 185 deg F
Terminal TypeScrew
TypeSafety Module
For monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety sw, For a broad range of machines of the general mechanical engineering
- 22.5 & 45 mm width
- 2 rows of terminals both on the top and bottom side (screw or spring removable terminals)
- Transparent sealable lid in front face, to protect the selector switches from manipulation
- Side connection for extension unit without need for external wiring except for XPSUAB & XPSUEP
- DIN-rail & direct wall mounting possibility
- 24 Vac/dc + Wide Range Power-Supply from 48 to 240 Vac/dc (only 2 supply variants for full coverage now)
- XPSUAT safety module name
- Monitoring antivalent contactsFor emergency stop, guard and light curtain monitoringMonitoring of pressure-sensitive 4-wire protective devices safety module application
- Emergency stop button with 2 NC contactsGuard monitoring with 1 or 2 limit switchesMonitoring 2 PNP sensorsMagnetic switch monitoringLight curtain monitoringRFID switchMonitoring of electro-sensitive protection equipment (ESPE)Sensing mat/edgesProximity sensor monitoringMonitoring 1 PNP + 1 NPN sensor function of module
- 0.5 s2 s4 s synchronisation time between inputs
- Automatic/manual/monitored type of start
- Internal, electronic input protection type
- 3 NO3 NO1 NC safety outputs
- 21 safety inputs
- 500 Ohm maximum wire resistance
- 0 to 900 s time delay range
- 4 pulsed output control outputs
- Pulsed output for diagnostics Z1, 20 mASemiconductor output Z2, 20 mA input/output type
- 24 V relay output minimum output voltage
TUV|CULus|IEC 60947-5-1|IEC 61508-1 functional safety standardIEC 61508-2 functional safety standardIEC 61508-3 functional safety standardIEC 61508-4 functional safety standardIEC 61508-5 functional safety standardIEC 61508-6 functional safety standardIEC 61508-7 functional safety standardISO 13849-1 functional safety standardIEC 62061 functional safety standard|PROP65: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov