EATON
EAGLE TRAFGF20W AF/GF TR DUPLEX 20A 125V WH
Factory Availability
EATON
EAGLE TRAFGF20W AF/GF TR DUPLEX 20A 125V WH
Factory Availability
Stanion #TRAFGF20WEAG
MFG #TRAFGF20W
UPC #032664747700
Product Overview
Eaton’s Slim Dual Function Arc Fault/Ground Fault (AF/GF) receptacles are designed with quick installation, ease-of-use and safety in mind. The updated design offers the slimmest in-box depths on the market that allows for easy installation, crisp design that is visually appealing and intuitive, and compliance with the latest UL and NEC safety standards. Eaton’s AF/GF receptacles are a great alternative to AF/GF breakers where local reset is desired.
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandEATON
Amperage Rating20 A
ColorWhite
Dimensions1.3 in W x 1.27 in D x 4.2 in H
Frequency Rating60 Hz
GradeSpecification
Manufacturer NameEaton
MaterialThermoplastic/Polypropylene
NEMA RatingNEMA 5-20R
Number of Poles2
Number of Wires3
SeriesTRAFGF20
Temperature Rating-31 to 150.8 deg F
Terminal TypeScrew
TypeDuplex Self-Test Tamper-Resistant
Voltage Rating125 VAC
Commercial, Institutional Buildings and Structures Applications
- Provides both arc fault protection per UL 1699A and ground fault protection per UL 943 in one convenient device
- Protects from both series and parallel arcs downstream from the outlet Branch circuit (OBC) AF/GF receptacle
- OBC AF/GF receptacles also protect from upstream series arcs
- Trip indicators make it easy to diagnose arc and ground faults
- Device self tests periodically to ensure proper function of both the ground fault and arc fault protection elements
- Meets and exceeds 10 kA short circuit testing and UL 943 safety standards
- Ground termination with back wire clamp provides secure wiring and reduces installation time
- Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
- Tapered backwire openings handle multiple wire sizes and types for application up to 10 AWG solid or stranded wire
- When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protection
- Lockout functionality prevents mis-wired line load connection and GFCI/AFCI circuitry damage
- Visual indicator light provides quick visual reference of a tripped or "end of life" condition
- Tamper-resistant shutters comply with 2014 NEC Article 406.12
- Terminal screws are backed out and ready to wiring
- https://www.youtube.com/watch?v=g8sFogYnr4w
CSA Certified|cULus Listed|NOM Certified|UL File No. 1699A|UL File No. 498|UL File No. 943|UL File No. E482200|UL94 V-2 Flammability Rated