SQD QO120CAFI MINIATURE CIRCUIT BREAKER 120V 20A
Square Dâ„¢
SQD QO120CAFI MINIATURE CIRCUIT BREAKER 120V 20A
Stanion #QO120CAFISQD
MFG #QO120CAFI
UPC #785901438359
Prop 65
Product Overview
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 1 pole QO circuit breaker is rated at 20A at 120VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a combination arc fault with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandSquare Dâ„¢
Amperage Rating20 A
Connection TypePressure Plate
Country of OriginMX
Dimensions2.91 in L x 0.75 in W x 4.75 in H
FrameQO/100 A
Frequency Rating50/60 Hz
Interrupt Rating10 kA
Manufacturer NameSchneider Electric
Mounting TypePlug-On
Number of Poles1
Phase1, 1 ph
Temperature Rating104 deg F
Trip TypeK-Curve/Thermal Magnetic
Voltage Rating120 VAC
Wire Size12 to 8 AWG, 14 to 8 AWG
For providing overload and short circuit protection designed to detect arc faults
- An arc fault circuit breaker opens the circuit and stops the arcing and high intensity heat before a fire is likely to ignite
- Special microprocessor based arc identification to differentiate necessary operational arcs (associated with loads such as electric motors, switches and receptacles) from actual arc faults which can cause damage and fires
- Differentiate true arc faults from chopped wave-forms associated with switched mode power supplies on electrical appliances, computers and lamp dimmers
- 14 - 8 AWG copper, 12 - 8 AWG aluminum
- Have special microprocessor-based arc identification to differentiate necessary operational arcs (associated with loads such as electric motors, switches and receptacles) from actual arc faults which can cause damage and fires
- K-Curve trip
- Combination ARC fault
Buy American Act Compliant|CSA 22.2 #5|RoHS Compliant|UL 489|PROP65: This product can expose you to chemicals including: Lead and Lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov