BUSS LPJ-2-1/4SP LOW-PEAK CLASS J T/D
Factory Availability
BUSS LPJ-2-1/4SP LOW-PEAK CLASS J T/D
Factory Availability
Stanion #LPJ21/4SPBUS
MFG #LPJ-2-1/4SP
UPC #051712522700
Product Overview
Bussmann's UL Class J fuse products extend both our Low-Peak family of products with our LPJ_SP and LPJ_SPI dual-element, time-delay fuses as well as our Limitron line offering fast-acting JKS fuses. The LPJ fuses provide industry leading 300,000 amp interrupting rating at 600Vac RMS Sym and 100kA Vdc while delivering a minimum of 10 seconds of 500 percent rated current ride-through performance which is ideal for sizing of high inrush loads. The LPJ products are available with optional permanent replace fuse indication. These UL Class J products in sizes 1 to 600 amps provide exceptional performance at 600 Vac and 300 Vdc (see spec sheets for specific details) in a compact size rejecting footprint
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandBussmann
Amperage Rating2.25 A
Body Size0.81 in Dia x 2.25 in L
Body TypeCylindrical
ClassJ
ElementDual
Indicating/Non-IndicatingNon-Indicating
Interrupt Rating100/300 kA
Manufacturer NameEaton
MaterialMelamine
Mounting TypeHolder
Rejection/Non-RejectionNon-Rejection
Response Time10 s at 500%
SeriesLPJ
Terminal TypeFerrule
TypeCurrent Limiting
Voltage Rating600 VAC/300 VDC
Branch Circuit Breaker Panelboard Mains, Industrial Control, Machinery Disconnects and Power Panelboard Applications, Safety and Security Systems
- Separate overload and short circuit elements provide time delay for sizing of high inrush loads linked with class J current limitation
- Selective co-ordination ratio of 2:1 (within Low-Peak⢠fuse family) prevents electrical shutdowns from extending beyond the failed circuit
- Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer
- Proper sizing can provide "no damage" type 2 motor starter protection for NEMAĀ® and IECĀ® motor controllers
- Space saving package for equipment down sizing
- Industry's only UL listed and CSA certified fuse with a 300 kea interrupt rating that allows for simple, worry free installation in virtually any application
- Fast short circuit protection and dual element, time delay performance provide ultimate protection
- Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak⢠fuses
- Consistent 2:1 ampacity ratios for all Low-Peak⢠fuses make selective co-ordination easy
- Long time delay minimizes needless fuse openings due to temporary overloads and transient surges
- Current limitation protects downstream components against damaging thermal and magnetic effects of short circuit currents
- Dual element fuses have lower resistance than ordinary fuses, hence they run cooler
- They can often be sized for back up protection against motor burnout from overload or single phasing if other overload protective devices fail
- https://www.youtube.com/watch?v=YMvqUyoETXk
CE Marked,RoHS Compliant