EATON
BUSS ECSR40 UL CLASS RK- 5 TIME DELAY
Factory Availability
EATON
BUSS ECSR40 UL CLASS RK- 5 TIME DELAY
Factory Availability
Stanion #ECSR40BUS
MFG #ECSR40
UPC #782634508366
Product Overview
ECNR/ECSR dual element fuses are recommended for AC power distribution system mains, feeders and branch circuits having inductive loads (motors, transformers) or non-inductive loads (lighting, heating) where the available short circuit current does not exceed 200000 rms symmetrical amperes. These dual element, time delay fuses have minimum industry standard time delay of 10 sec at 5 times the fuse rating (8 sec minimum for 250 VAC, 30 A and less). The time delay characteristics of these fuses typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved over current protection. These fuses will override normal equipment current surges to reduce unnecessary fuse openings. They are the most popular fuses used in the industry and the most economical for most applications, especially motors and transformers. They have moderate current limitation.
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandEATON
Amperage Rating40 A
Body Size1.06 in Dia x 5.5 in L
Body TypeBullet
ClassRK5
Country of OriginMX
ElementDual
Indicating/Non-IndicatingNon-Indicating
Interrupt Rating200 kA
Manufacturer NameEaton
Mounting TypeHolder
Rejection/Non-RejectionRejection
Response Time10 s at 500%
SeriesECSR
Terminal TypeFerrule End x Ferrule End
TypeCurrent Limiting
Voltage Rating600 VAC
AC Power Distribution System Mains, Feeders, Branch Circuits, Motors and Motor Branch Circuits, Transformers and Inductive Loads, Lighting, Heating and Non-inductive Loads Applications
- True dual element construction allows sizing of 125% FLA for motor backup protection
- Superior overload and cycling capabilities
- Current limiting provides component short circuit protection
- Provides motor overload ground fault and short circuit protection
- Provides a good deg of short circuit protection (greater current limitation to help protect downstream components from high fault current
- The time delay feature makes it possible to use fuse amp ratings, which are much smaller than those of non-time delay fuses
- Considerable cost saving occurs by permitting the use of smaller size switches, panels and fuses themselves
- Helps protect motors against burnout from overloads and single phasing when sized properly
- Gives motor running back-up protection to motors without extra costs
- https://www.youtube.com/watch?v=YMvqUyoETXk
Class 1422-02 File No. 700489|UL File No. E162363|CE Certified|CSA C22.2 No. 248.12