SQD 8502SAO12V02S CONTACTOR 600VAC 9AMP NE
SQD 8502SAO12V02S CONTACTOR 600VAC 9AMP NE
Stanion #8502SAO12V02SSQD
MFG #8502SAO12V02S
UPC #785901770725
Prop 65
Product Overview
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 00 non-reversing contactor has a 9 ampere rating. Three phase NEMA Size 00 contactors have 1.5 HP at 200 and 230 VAC and 2 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is an open device without an enclosure. This contactor is 4.34 inches tall, 3.22 inches wide and 4.22 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandSquare Dâ„¢
Coil Power Rating1.5 hp at 200/230 VAC/2 hp at 460/575 VAC
Coil Voltage110/120 VAC
Connection TypeScrew Clamp
Contact Rating9 A, 9:00 AM
Contact TypeNon-Reversing
Country of OriginUS
Dimensions3.23 in W x 4.22 in D x 4.33 in H
Enclosure TypeOpen
Frequency Rating50/60 Hz
Manufacturer NameSchneider Electric
Number of Poles3
Operating Cycles6 cpm
Operating Temperature0 to 40 deg C
Series8502
SizeSZ 00
Terminal TypeScrew
Type3-Phase Type S
Wattage1.1 kW at 200/230 V/1.5 kW at 460/575 V
Construction, Infrastructure, Industrial Markets, Commercial Office Buildings and Building Automation Applications
- A normally open holding circuit contact for three wire control is provided as standard
- For flexibility field-installable or factory modified accessories include auxiliary contacts, power poles and cover mounted control stations
- Bell crank design promotes superior electrical and mechanical life
- Serviceable by replacing contacts and coils rather than replacing the entire product
CE Certified|CSA File No. LR60905/60905 Class 3211-04|ECCN: EAR99|IEC 947-4-1|UL File No. E78351|CCN Guide No. NLDX|PROP65: This product can expose you to chemicals including: Antimony oxide and Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov