3M 5418A COLD SHRINK QS- III SPLICE KIT 5418A 500-1000 KCMIL
3M 5418A COLD SHRINK QS- III SPLICE KIT 5418A 500-1000 KCMIL
Stanion #5418A3M
MFG #5418A
UPC #54007421283
Product Overview
3M™ cold shrink QS III in-line CN/JCN cable splices 5456A-WG, 5457A-WG and 5458A-WG are in-line splices for joining 25/28 kV jacketed concentric neutral (JCN) or concentric neutral (CN) power cables. It is a cold shrink design. The cold shrink splice body is a 1 piece molded design made of specially formulated silicone rubbers, while the jacketing is made of EPDM rubber for its special physical properties. Each splice is high voltage production-tested to ensure reliability. Kits can be ordered with connectors packed in the kit or the kit and connector can be ordered as separate items. Meets requirements of IEEE 404. Each kit makes one splice. Note:5456A-WG, 5457A-WG and 5458A-WG are partially jacketed splices containing built-in bleeder wires. Additional end user materials are required to convert to full jacketing.
- Attributes
- Documents
- Application
- Includes
- Item Features
- Standards
Brand3M™
Cable TypeConcentric Neutral/Jacketed Concentric Neutral
ColorBlack
Conductor Size500 to 1000 kcmil
Country of OriginUS
Dimensions3 to 3-1/4 in Dia
Insulation Size1.08 to 1.7 in OD
Manufacturer Name3M
MaterialEPDM/Silicone Rubber
Number of Conductors1
SeriesQS-III 5418A
Splice Length32 in
Temperature Rating105 to 140 deg C
TypeCold Shrink In-Line
Voltage Rating25/28 kV
Aerial, Direct Burial and Submerged Location Applications
3M™ Cold Shrink Silicone Rubber Splice Body, 3M™ Cold Shrink Adapter Tube, 3M™ Cold Shrink Jacketing Tube, (2) 3M™ Red Compound Tubes P55/R, (6) Scotch® Mastic Sealing Strips 2230, (2) Scotch® Rubber Mastic Tape 2228 Rolls, Neutral Pad, 3M™ Cable Cleaning Pad CC-3, Cable Preparation Template and Instruction Booklet
- In-line splice for joining jacketed concentric neutral (JCN) and concentric neutral (CN) power cables
- Special electrode design of the kit reduces the electrical stress at a critical cable/splice interface
- Silicone rubber splice body provides good high and low temperature performance and the EPDM rubber jacket offers physical protection
- Factory tested partial discharge and AC ensure reliability
- Polyolefin foam, copper conductor
- 0.8 to 1.84 in OD connector
- 6-3/4 in aluminum/copper compression length, 7-1/2 in copper compression length, 7.83 in shear bolt connector length
- 1090 psi tensile strength
- 610% elongation
- 370 V/mil dielectric strength
- 500 kcmil, 750 kcmil, 1000 kcmil conductor size
- 1/case
IEEE 404