SQD 8536SAG12V08 STARTER 600VAC 9AMP NEMA
SQD 8536SAG12V08 STARTER 600VAC 9AMP NEMA
Stanion #8536SAG12V08SQD
MFG #8536SAG12V08
UPC #785901743484
Prop 65
Product Overview
Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 00 non-reversing starter has an 9 ampere rating. This NEMA Size 00 motor starter has 3 phase ratings of 1.5 HP at 220 and 230 VAC and 2 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 208 VAC 60 Hz operating coil wired for common control. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this starter. Enclosure is 10.00 inches tall, 6.00 inches wide and 5.56 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
- Attributes
- Documents
- Application
- Includes
- Item Features
- Standards
- Warranty
BrandSquare D™
ActionNon-Reversing
Amperage Rating9 A, 9:00 AM
Coil Voltage208 VAC
Connection TypeScrew Clamp
Country of OriginMX
Dimensions5.98 in W x 5.55 in D x 10 in H
Enclosure TypeNEMA 1
Frequency Rating50/60 Hz
Manufacturer NameSchneider Electric
MaterialSheet Steel
Motor Power1-1/2 hp at 200/230 VAC/2 hp at 460/575 VAC
Number of Poles3
Operating Cycles6 cpm
Operating Temperature0 to 40 deg C
Phase3, 3 ph
Reset Type(3) Thermal Melting Alloy
Series8536
Starting ModesMagnetic
TypeType S
Voltage Rating600 VAC
Wattage1.1 kW at 200/230 VAC, 1.5 kW at 460/575 VAC
Constructions, Infrastructure, Industrial Markets, Commercial Office Buildings, Building Automation, Starting and Stopping Of AC Squirrel Cage Motors Applications
Separate Control Circuit
- Used for full voltage starting and stopping AC squirrel cage motors
- NEMA type 1 general purpose enclosure
- https://www.youtube.com/embed/W3jC7ckgcBo
CE Certified|IEC 947-4-1|CSA 60905 Class 3211-04|ECCN: EAR99|UL File No. E78351 Guide No. NLDX|PROP65: This product can expose you to chemicals including: Antimony oxide and Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
18 Months