SQD QO115PAFGF QO DUAL 10KA MCB
Product Overview
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. This 1 pole QO circuit breaker is rated at 15A at 120VAC. This unit provides 10kA breaking capacity and plug in mounting. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This product includes a dual function feature with plug on neutral. This provides combination arc fault and ground fault protection. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555 This circuit breaker has combination ARC fault and ground fault. The pressure plate connectors will accept one 14 AWG to 8 AWG copper or 12 AWG to 8 AWG aluminum wire. This circuit breaker has a height of 4.75 inches, a width of 0.75 inch and a depth of 2.91 inches. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
- Attributes
- Documents
- Item Features
- Standards
BrandSquare D™
Actuator TypeToggle
Amperage Rating15 A
Connection TypePressure Plate
Country of OriginMX, US
Dimensions4.10 in H x 0.75 in W x 2.72 in D
Frequency Rating50, 60 Hz
Interrupt Rating10 kA at 120 VAC
Manufacturer NameSchneider Electric
Mounting TypePlug-On
Number of Poles1
SeriesQO Series
Temperature Rating104 deg F
Trip TypeShunt
TypeCombination ARC And Ground Fault
Voltage Rating120 VAC
Wire Size14 to 8 AWG Copper, 12 to 8 AWG Aluminium
- QO one-pole standard circuit breakers (10 A to 70 A)
- QO two-pole standard circuit breakers (10 A to 200A)
- QO three-pole standard circuit breakers (10 A to 100 A)
- QO tandem circuit breakers (15 A to 20 A)
- QO ground-fault circuit interrupters (1- and 2-pole, 15 A to 60 A; 3-pole 15 A - 50 A)
- QO-EPD circuit breakers with 30 mA equipment ground-fault protection (1-pole, 2-pole, 15 A to 60 A; 3-pole, 15 A - 50 A)
- QO arc-fault circuit interrupters (1-pole, 15 A and 20 A)
- QO combination arc-fault circuit interrupters (1-pole, 15 A and 20 A)
- QO Dual Function Circuit Breakers (1-pole, 15 A and 20 A)
- QO-K circuit breakers, key operated (1-pole, 10 A to 30A)
- QO-SWN circuit breakers with switch neutral common trip, NEC 514-5 (2- and 3-pole, 10 A to 50 A)
- QO-HID circuit breakers for circuits feeding fluorescent or high intensity discharge (1-, 2- and 3-pole, 15 A to 50 A)
- A full line of factory installed accessories, such as shunt trips, auxiliary switches and alarm switches, is also available
- QO sub-feed lugs, 2-pole rated 60A, 125A and 225A, 3-pole rated 125A
UL Listed