SQD BDA160203 MOLDED CASE CIRCUIT BREAKER 347
SQD BDA160203 MOLDED CASE CIRCUIT BREAKER 347
Stanion #BDA160203SQD
MFG #BDA160203
UPC #3606481151162
Product Overview
PowerPacT B-Frame brings thermal-mechanical circuit protection in a compact size and offers a wide range of accessories, auxiliaries, and connection options. This PowerPacT B-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600Y/347VAC. All PowerPacT B-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT B-Frame circuit breakers come in 1 to 4-pole unit mount construction and in 1 to 3-pole I-Line construction. I-Line circuit breakers come with a shrouded I-Line plug on jaw. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT B, 20A, 1 pole, circuit breaker has a breaking capacity of 14kA at 600Y/347VAC. This circuit breaker has a continuous current rating of 80% with a B phase connection. PowerPacT B circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Attributes
- Documents
- Application
- Item Features
- Standards
BrandSchneider Electric
Actuator TypeToggle
Amperage Rating20 A
ColorGray
Connection TypeI-Line™/Mechanical Lug
Country of OriginMX
Dimensions5.39 in H x 1.06 in W x 3.5 in D
Enclosure TypeIP40/IK07
FrameB
Frequency Rating50/60 Hz
Interrupt Rating14 kA
Manufacturer NameSchneider Electric
Number of Poles1
Phase1
Temperature Rating-13 to 158 deg F
Trip Range400 to 600 A
Trip TypeThermal/Magnetic
TypeType BDA
Voltage Rating600Y/347 VAC
Wire Size14 to 2/0 AWG Al/Cu
Industrial Control Panels, Commercial OEM, Electrical Distribution Equipment, Commercial Buildings and Industrial Building Applications
- In case of a short circuit, increased magnetic flux causes the plug on connectors of the circuit breaker to tighten their grasp on the busbars
- I-Line connectors and circuit breaker mounting bracket are integral parts of I-Line circuit breakers and cannot be removed or replaced
- I-Line circuit breakers come with aluminum mechanical load-side lugs or optional copper mechanical lugs, EverLink lugs with control wire terminals or terminal nuts to connect to busbars or to compression (crimp) lugs
UL 489|CSA C22.2 No. 5|EN/IEC 60947-2|EN/IEC 60947-5-1|GB 14048.2|NMX J-266|NEMA AB1|CE Certified|CCC Certified|EAC Approved|NOM Certified|PROP65: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov