TORK 3000 BUTTON FLUSH MOUNT ON 1-5FC/OFF 3-15F
Product Overview
The TORK 3000 Flush Mounting Photocontrol with Lexan® Housing provides professional-grade performance for a range of residential and commercial applications. This photocontrol light sensor automatically detects nightfall, allowing you to run exterior lights from dusk to dawn. Use TORK flush mount photocontrols to automate ON/OFF switches for pole lanterns, lawn lighting and walkway applications. The TORK 3000 saves you energy and money, while adding security to your property at night with a time delay feature that prevents car headlights or other stray city lighting from accidentally turning the sensor OFF. A conformal coated cadmium sulphide photocell resists the effects of moisture and airborne contaminants and responds to the light spectrum near to that of a human eye. Additionally, a two-minute OFF delay prevents false switching from quick light changes due to headlights or lightning. This photocontrol is easy to mount through a .6875" hole in post lantern or lighting fixture using a 3/4" long, 3/8" NPT threaded stem with a mounting gasket and nut included. Rated for 120VAC. When choosing a photocontrol light sensor you can rely on, trust in TORK, a pioneer in the industry since 1922.
- Attributes
- Documents
- Application
- Includes
- Item Features
- Standards
- Warranty
BrandNSI
Ballast Load1200 VA
Contact Form1NC-SPST
Country of OriginCN
Dimensions2 in H x 1 in W x 1-1/2 in D
Environmental Conditions-40 to 140 deg F Operating Temperature
Frequency Rating50/60 Hz
Manufacturer NameNSi Industries
MaterialLexan
Mounting TypeBox/Fixture, Flush
Sensitivity1 to 5 FC (ON)/3 to 15 FC (OFF) Ratio
Sensor TypeCadmium Sulfide Cell
Series3000
Timing Range2 min
Tungsten Rating2000 W
TypeButton
Voltage Rating120 VAC
Wire Size16 AWG
Pole Lanterns, Lawn Lighting and Walkways
3/4 in Flush Mount with Gasket and Nut
- Conformal coated cadmium sulphide photocell resists effects of moisture and airborne contaminants
- Photocell responds to the light spectrum near to that of a human eye
- Delay of up to two minutes to prevent false switching due to light from passing vehicles, lightning and more
- Control housing is weather resistant molded Lexan® with ultrasonically welded seams
- Flush mounting through 11/16 in hole in post lantern or lighting fixture, 3/8 in NPT, stem 3/4 in long
- Works with screw base CFL
- On and Off time delay
- Cadmium sulphide, conformal coated 1/2 in diameter cell
- Three color coded, minimum 9 in wire leads, 16 AWG, rated for 105 deg C lead wires
- Averages under 1 W power consumption
- On fail mode
cULus Listed|ANSI Specified|UL 773A
5 Years