GE FBN36TE030RV 30A MCCB 3P 600Y347
Product Overview
Record Plus® represents the very latest in molded case circuit breaker design. Utilizing design features such as double break rotary contact structures and advanced ablative materials to enhance interruption, record Plus® is capable of interrupting ratings up to 200 kA (FC maximum is 150 kA). high kAIC ratings, selective coordination, reduced arc flash energy and current limitation embody the core design principles of record Plus®. FC 100 circuit breakers are supplied with factory installed non-user interchangeable thermal magnetic trip units and can be supplied with or without lugs. FC is available in 2 and 3-pole versions, both in a 3-pole footprint. record Plus® product numbers ending in R or R0 do not include lugs. an R1 suffix indicates that the breaker is supplied with line and load lugs, R2 indicates load lugs and R3 indicates line lugs. RV suffixed product numbers include load lugs and line connections specifically designed for GE type AD panels. all frames use common internal accessories (auxiliary switches, UV releases, shunt trips and bell alarms) UL listed for field installation. UL listed maximum short circuit ratings at 480 VAC are 150 kA for the 100 A frames and 200 kA for the 600 A frames. unless noted otherwise, all circuit breakers and accessories are listed in UL file No. E11592.
- Attributes
- Documents
- Application
- Includes
- Item Features
- Standards
BrandGE
Actuator TypePivot/Toggle Handle
Amperage Rating30 A
Connection TypeLoad Lug/Panel
Dimensions4.11 in W x 3.28 in D x 6.45 in H
FrameFB100
Frequency Rating50/60 Hz
Interrupt Rating150 kA at 240 VAC/65 kA at 480 VAC
Manufacturer NameABB
MaterialPlastic
Mounting TypePanel
Number of Poles3
Phase3
Temperature Rating-40 to 80 deg C
Trip TypeThermal Magnetic
TypeType FBN
Voltage Rating600Y/347 VAC
Wire Size10 to 4 AWG
Other
Commercial, Industrial, Current Limiting, Naval, Electrical Distribution and Control Applications
FCALK13 Lug
- Broad product line to meet virtually any application need
- Reduced downtime
- A tripped breaker is easily spotted and can be immediately reset after the fault has been corrected
- Eliminates single phasing
- A common trip bar disconnects all poles simultaneously on both overload and short circuits
- Offers application flexibility through the use of a wide variety of accessory devices and special attachments
- Repetitive operation no fuses to replace
- Breakers can be repetitively tested
- Fuses must be destroyed to confirm calibration accuracy
- 150 kA at 240 VAC, 65 kA at 480 VAC interrupt rating
cUL File No. 489|HACR Rated|UL File No. 489|UL File No. E11592